Ruskin Fire/Smoke Dampers
FSD35
Dampers
For More Information:
![fsd35-300x300 fsd35-300x300](https://www.svl.com/wp-content/uploads/2023/04/fsd35-300x300-1.webp)
UL 555/555S 1.5 hr./Class III, V-Groove Blade, 2,000 fpm and 4″ w.g. max, Optional Sleeve Dampers
The FSD35 Combination Fire/Smoke Damper is both UL555 and UL555S Classified. It is rated as a 1-1/2 hour fire damper and a Leakage Class III Smoke damper. It features:
- Triple V-Groove Blades.
- Maximum rating of 2,000 fpm and 4″ w.g.
- UL approval for dual directional airflow.
- Failsafe design, which enables the damper to automatically assume the desired position when fire or smoke (if smoke detector is present) interrupts operational power.
- The EFL or PFL heat-actuated release devices permit controlled closure through the actuator and are automatically remote resettable after test, smoke detection, or power failure conditions.
- Galvanized steel construction.
FSD36
Dampers
For More Information:
![fsd36-300x300 fsd36-300x300](https://www.svl.com/wp-content/uploads/2023/04/fsd36-300x300-1.webp)
UL 555/555S 1.5 hr./Class II, V-Groove Blade, 2,000 fpm and 4″ w.g. max, Optional Sleeve
The FSD36 Combination Fire/Smoke Damper is both UL555 and UL555S Classified, and rated as a 1-1/2 hour fire damper and a Leakage Class II Smoke damper. It features:
- Maximum velocity of 2,000 fpm.
- Maximum 4″ static pressure.
- UL tested for dual directional airflow.
- Failsafe design, which enables the damper to automatically assume the desired position when fire or smoke (if smoke detector is present) interrupts operational power.
- The EFL or PFL heat-actuated release devices permit controlled closure through the actuator and are automatically remote resettable after test, smoke detection, or power failure conditions.
- Galvanized steel construction.
FSD60
Dampers
For More Information:
![ruskin-fsd60-300x300 ruskin-fsd60-300x300](https://www.svl.com/wp-content/uploads/2023/04/ruskin-fsd60-300x300-1.webp)
UL 555/555S 1.5 hr./Class I, Airfoil Blade, 4,000 fpm and 8″ w.g. max, Optional Sleeve
The FSD60 Combination Fire/Smoke Damper are both UL555 and UL555S Classified, and rated as a 1-1/2 hour fire damper and a Leakage Class I Smoke damper. It features:
- Maximum velocity of 4,000 fpm.
- Maximum 8″ static pressure
- UL approval for dual directional airflow
- Failsafe design, which enables the damper to automatically assume the desired position when fire or smoke (if smoke detector is present) interrupts operational power
- The EFL or PFL heat-actuated release devices permit controlled closure through the actuator and are automatically remote re-settable after test, smoke detection, or power failure conditions
- Galvanized steel construction
CDO25
Dampers
For More Information:
![cdo25-300x300](https://www.svl.com/wp-content/uploads/2023/04/cdo25-300x300-1.webp)
Galv. oval, flat blade, Class II leakage, heavy duty, 4000 FPM, 10″ w.c. max.
The CDO25 is an oval control damper that features:
- Volume control.
- Steel construction with aluminum paint finish.
- When equipped with blade seals, provides positive shut-off.
CD35
Dampers
For More Information:
![cd35-300x300 cd35-300x300](https://www.svl.com/wp-content/uploads/2023/04/cd35-300x300-1.webp)
Galv. rectangular, v-groove, medium duty, no seals, 2000 FPM, 5″ w.c. max.
The CD35 commercial control damper offers sturdy, steel construction with interlocking frame design. It locks together without bolts, screws, or rivets that could shake loose. It also features:
- Frame corners that are internally braced to reduce racking.
- Axles that positively lock to blades without screws or welds.
- Non-stick, noncorrosive bearings that assure long life and ease of operation.
- Low maintenance operation.
CD36
Dampers
For More Information:
![cd36-300x300 cd36-300x300](https://www.svl.com/wp-content/uploads/2023/04/cd36-300x300-1.webp)
Galv. rectangular, v-groove, class II leakage, medium duty, 3000 FPM, 5″ w.c. max.
The CD36 commercial control damper offers sturdy, steel construction with interlocking frame design. It locks together without bolts, screws, or rivets that could shake loose. It also features:
- Frame corners that are internally braced to reduce racking.
- Axles that positively lock to blades without screws or welds.
- Non-stick, noncorrosive bearings that assure long life and ease of operation.
- Low maintenance operation.
CD50
Dampers
For More Information:
![ruskin-cd50-300x300 ruskin-cd50-300x300](https://www.svl.com/wp-content/uploads/2023/04/ruskin-cd50-300x300-1.webp)
Alum. rectangular, airfoil, class IA leakage, heavy duty, 6000 FPM, 13″ w.c. max.
Ruskin model CD50 offers HVAC design engineers an ultra-low leak high performance damper which provides:
- Energy savings for building owners
- Low noise generation and lowest pressure drop
- Low maintenance
CD60
Dampers
For More Information:
![cd60-300x300 cd60-300x300](https://www.svl.com/wp-content/uploads/2023/04/cd60-300x300-1.webp)
Galv. rectangular, airfoil, class IA leakage, heavy duty, 6000 FPM, 13″ w.c. max.
Ruskin model CD60 offers HVAC design engineers an ultra-low leak high performance damper which provides:
- Energy savings for building owners
- Low noise generation and lowest pressure drop
- Low maintenance